Applicable Scenarios

ScenarioDescription
Cluster initializationSet time_zone after deployment based on business location or a unified standard
Cross-time-zone data ingestionIngest data with or without time zone information through Stream Load, Broker Load, and similar methods
Function result alignmentAdjust the time zone for the return values of functions such as NOW(), CURTIME(), and FROM_UNIXTIME
Daylight saving time handlingHandle named time zones (such as America/Los_Angeles) that involve daylight saving time transitions
Time zone data updateUpdate the time zone data on the BE machines after IANA releases a new tzdata version

Basic Concepts

Doris has the following two time-zone-related parameters:

ParameterModifiableDescription
system_time_zoneNoSet automatically by the system based on the machine's local time zone when the server starts. It cannot be modified after being set.
time_zoneYesThe current time zone of the cluster. It is the same as system_time_zone when the cluster starts and remains unchanged unless modified manually.

View and Set the Time Zone

View the Current Time Zone

Run the following SQL statement to view the time-zone-related variables:

show variables like '%time_zone%';

Set the Time Zone

Modify time_zone with a SET statement:

SET [global] time_zone = 'Asia/Shanghai';
  • Without the global keyword: takes effect only in the current session.
  • With the global keyword: Doris FE persists the parameter, and it takes effect for all subsequent new sessions.

Time Zone Data Source

Time zone data includes time zone names, corresponding time offsets, daylight saving time changes, and other information. On the BE machine, the data is sourced from the directory returned by the TZDIR command. If the command is not supported, the source is the /usr/share/zoneinfo directory.

Time Zone Value Formats

Time zone values can be given in several formats. The following are the standard formats that Doris fully supports:

TypeExampleDescription
Standard named time zoneAsia/Shanghai, America/Los_Angeles, Etc/GMT+3Sourced from the local time zone data
Standard offset format+02:30, -10:00Special offsets such as +12:03 are not supported
Abbreviated time zoneGMT, UTCEquivalent to the +00:00 time zone
Abbreviated time zoneCSTEquivalent to the Asia/Shanghai time zone
Single letter ZZRepresents the Zulu time zone, equivalent to the +00:00 time zone

In addition, letter parsing is case-insensitive.

Note

Because of implementation differences, some other formats are currently supported in certain ingestion methods. Production environments must not rely on formats that are not listed here. Their behavior may change at any time. Watch the changelog of each release for related updates.

Effects of the Time Zone

Effect on Functions

The time zone affects the values returned by time functions such as NOW() and CURTIME(), as well as the time values shown in SHOW LOAD and SHOW BACKENDS.

However, it does not affect the LESS THAN values of time-typed partition columns in CREATE TABLE, and it does not affect the displayed values of data stored as DATE or DATETIME types.

Functions affected by the time zone:

FunctionBehavior
FROM_UNIXTIMEGiven a UTC timestamp, returns the date and time in the time zone specified by the Doris session time_zone. For example, when time_zone is CST, FROM_UNIXTIME(0) returns 1970-01-01 08:00:00.
UNIX_TIMESTAMPGiven a date and time, returns the UTC timestamp under the time zone specified by the Doris session time_zone. For example, when time_zone is CST, UNIX_TIMESTAMP('1970-01-01 08:00:00') returns 0.
CURTIMEReturns the current time in the time zone specified by the Doris session time_zone.
NOWReturns the current date and time in the time zone specified by the Doris session time_zone.
CONVERT_TZConverts a date and time from one specified time zone to another.

Effect on Time Types

DATE / DATETIME Types

For the DATE and DATETIME types, time zone conversion is supported during data ingestion:

  • Data with time zone: For example, given 2020-12-12 12:12:12+08:00 and a Stream Load header timezone of +00:00, the actual value stored in Doris is 2020-12-12 04:12:12.
  • Data without time zone: For example, 2020-12-12 12:12:12 is treated as an absolute time, and no conversion occurs.

TIMESTAMPTZ Type

The TIMESTAMPTZ type also supports time zone conversion during data ingestion: the input time value is uniformly converted to UTC (Coordinated Universal Time), and the output applies the current session's time zone.

  • Data with time zone: For example, for 2020-12-12 12:12:12+08:00, Doris uses the provided time zone information for the conversion.
  • Data without time zone: For example, for 2020-12-12 12:12:12, Doris uses the current session's time zone setting for the conversion.

The current session's time_zone affects the output of the TIMESTAMPTZ type. For example, if the current session has time_zone="+08:00" and the TIMESTAMPTZ value is 2020-12-12 12:12:12+08:00, changing time_zone changes the output value:

set time_zone = "+08:00";

select * from tz_test;
+---------------------------+
| tz |
+---------------------------+
| 2020-12-12 12:12:12+08:00 |
+---------------------------+

set time_zone = "+07:00";

select * from tz_test;
+---------------------------+
| tz |
+---------------------------+
| 2020-12-12 11:12:12+07:00 |
+---------------------------+

Daylight Saving Time

Daylight saving time means that the actual offset of a named time zone changes within a certain date range.

For example, the America/Los_Angeles time zone has one daylight saving time transition each year, starting around March and ending around November. When daylight saving time begins in March, the actual offset of America/Los_Angeles changes from -08:00 to -07:00. When daylight saving time ends in November, it changes back from -07:00 to -08:00.

If you do not want to enable daylight saving time, set time_zone to -08:00 instead of America/Los_Angeles.

Best Practices

Handling Time-Zone-Sensitive Data

Time zone issues involve three main factors:

  1. Cluster time zone: the session variable time_zone.
  2. Ingestion time zone: the header timezone specified during Stream Load, Broker Load, and similar ingestion methods.
  3. Data time zone: the time-zone literal in the data (for example, the +08:00 in 2023-12-12 08:00:00+08:00).

Doris currently supports ingesting data from any time zone into Doris. Because Doris time types such as DATETIME do not carry time zone information internally and the stored data does not change with the time zone after ingestion, time data ingested into Doris falls into two categories:

  1. Absolute time

    Absolute time means the data scenario is time-zone-independent. For this kind of data, do not include any time zone suffix during ingestion. The data is stored as is.

  2. Time in a specific time zone

    Time in a specific time zone means the data scenario is time-zone-dependent. For this kind of data, include the specific time zone suffix during ingestion. During ingestion, the data is converted to the time zone specified by the Doris cluster time_zone or by the header timezone in Stream Load or Broker Load.

    After ingestion, this kind of data is stored as the absolute time in the time zone specified during ingestion. Subsequent ingestion and queries must keep the same time zone to avoid disrupting the meaning of the data.

Insert Statement Example

Doris > select @@time_zone;
+---------------+
| @@time_zone |
+---------------+
| Asia/Shanghai |
+---------------+

Doris > insert into dt values('2020-12-12 12:12:12+02:00'); --- The ingested data specifies the time zone as +02:00

Doris > select * from dt;
+---------------------+
| dt |
+---------------------+
| 2020-12-12 18:12:12 | --- Converted to the Doris cluster time zone Asia/Shanghai. Subsequent ingestion and queries must keep this time zone.
+---------------------+

Doris > set time_zone = 'America/Los_Angeles';

Doris > select * from dt;
+---------------------+
| dt |
+---------------------+
| 2020-12-12 18:12:12 | --- If time_zone is changed, the time value does not change, and its meaning at query time becomes inconsistent.
+---------------------+

Stream Load Example

For ingestion methods such as Stream Load and Broker Load, time zone conversion can be performed by specifying the header timezone. For example:

cat dt.csv
2020-12-12 12:12:12+02:00

curl --location-trusted -u root: \
-H "Expect:100-continue" \
-H "strict_mode: true" \
-H "timezone: Asia/Shanghai" \
-T dt.csv -XPUT \
http://127.0.0.1:8030/api/test/dt/_stream_load
Doris > select @@time_zone;
+---------------+
| @@time_zone |
+---------------+
| Asia/Shanghai |
+---------------+

Doris > select * from dt;
+---------------------+
| dt |
+---------------------+
| 2020-12-12 18:12:12 | --- Converted to the Doris cluster time zone Asia/Shanghai. Subsequent ingestion and queries must keep this time zone.
+---------------------+
tip
  • For ingestion methods such as Stream Load and Broker Load, the header timezone overrides the Doris cluster time_zone, so keep them consistent during ingestion.
  • For ingestion methods such as Stream Load and Broker Load, the header timezone affects the functions used during ingestion conversion.
  • If the header timezone is not specified during ingestion, the current cluster time zone is used by default.

Best Practice Summary

Best practice
  1. Confirm the time zone the cluster represents before use, set time_zone, and do not change it afterward.
  2. Set the header timezone to match the cluster time_zone during ingestion.
  3. For absolute time, do not include a time zone suffix during ingestion. For time-zone-aware time, include the specific time zone suffix during ingestion. After ingestion, the data is converted to the Doris time_zone time zone.

Daylight Saving Time Recommendations

The start and end times of daylight saving time come from the current time zone data source and are not necessarily exactly the same as the official times confirmed in the relevant region for the current year. This data is maintained by ICANN.

To make sure daylight saving time behavior matches the official rules of the current year, make sure the data source used by Doris is the latest time zone data published by ICANN. See below for the download method.

Update Time Zone Information

Real-world time zone and daylight saving time data changes from time to time for various reasons. IANA regularly records these changes and updates the corresponding time zone files. To keep the time zone information in Doris consistent with the latest IANA data, use one of the following two methods:

Method 1: Update with a Package Manager

Depending on the package manager used by the current operating system, update the time zone data directly with the corresponding command:

# yum
sudo yum update tzdata
# apt
sudo apt update tzdata

The data updated by this method is located under the system $TZDIR (usually /usr/share/zoneinfo).

For most Linux distributions, tzdata is not synchronized in a timely manner through the package manager. If you have higher requirements for the accuracy of time zone data, pull the data periodically published by IANA directly:

wget https://www.iana.org/time-zones/repository/tzdb-latest.tar.lz

Then follow the README in the extracted folder to generate the specific zoneinfo data. Copy the generated data to the $TZDIR directory and overwrite the existing files.

Important

After all the above operations are completed on the BE machine, the corresponding BE must be restarted for the changes to take effect.

FAQ

Q: After changing time_zone, the query results for existing data change unexpectedly?

Types such as DATETIME do not carry time zone information internally, and changing the cluster time zone after ingestion does not change the stored values. Confirm the cluster time zone before use, set time_zone, and do not change it afterward.

Q: The time offset of Stream Load ingested data does not match expectations?

The header timezone is inconsistent with the cluster time_zone. Keep the header timezone consistent with the cluster time_zone.

Q: The time returned by NOW() does not match the local time?

The cluster time_zone is inconsistent with the local time zone. Adjust it with SET global time_zone = 'Asia/Shanghai'.

Q: The daylight saving time transition of a named time zone does not match the current-year rules?

The tzdata on the BE machine is outdated. Update tzdata with a package manager or by pulling the IANA tzdata directly, then restart the BE.

Q: I am using America/Los_Angeles but do not want to enable daylight saving time?

Named time zones include daylight saving time rules. Use a fixed offset format such as -08:00 instead.

Further Reading